NobelActive®

An implant like no other.

The unique implant design for high primary stability and esthetic excellence. Now available with single prosthetic connection, NobelActive S.

Backed by more than 15 years of clinical experience1

A 97.9% mean survival rate across 107 clinical studies, 22,500+ NobelActive implants, and 6,300+ patients with up to 12 years of follow-up demonstrates the long-term reliability of NobelActive.2

Designed for high primary stability, even in soft bone and extraction sockets.

Allows for immediate loading protocols from single tooth to full-arch restorations.

Optimized prosthetically-driven implant positioning in the hands of experienced clinicians.

NobelActive S series

NEW

NobelActive® S 
One smart connection

NobelActive S combines the implant’s iconic stability with a single NP prosthetic connection across all diameters. The design incorporates enhanced platform shifting, and full compatibility with existing protocols, instrumentation, and NP restorative solutions.

Expand your patient services with NobelActive implants

NobelActive implants help you achieve high primary stability when you’re dealing with soft bone, extraction sockets, or the esthetic region. They're particularly suitable for more demanding situations that require immediate implant placement or immediate function.3-10

    Double-lead thread

    Fast engagement in the osteotomy compared to single lead thread.

    Reverse cutting blades

    Enable experienced clinicians to adjust the implant’s position during placement for optimized restorative alignment.

    Expanding tapered body

    Condenses bone gradually during insertion allowing for high primary stability and enabling immediate loading.

    Sharp cutting blades

    Allow for under-preparation of the surgical site to help achieve high primary stability in demanding situations such as soft bone or extraction sockets.

    NobelActive connections

    NobelActive 3.0 implants for when there's limited space

    NobelActive 3.0 is designed for narrow-space situations, such as maxillary lateral and mandibular lateral and central incisors. It preserves marginal bone and soft tissue for natural-looking esthetics over time.3,6,11,12

    NobelActive 3.0
    NobelActive WP

    NobelActive WP for posterior cases

    NobelActive WP is designed for posterior cases that require a wider base. The 5.5 mm platform supports an optimized molar emergence profile when subcrestal placement is challenging.

    Aim for esthetic excellence

    Discover NobelActive with us

    Dr. Eric Rompen

    Belgium

    “An incredibly effective implant that provides excellent stability even in compromised sites. Because of its unique features to preserve the biology of marginal hard and soft tissues, NobelActive has become my number-one implant in the esthetic area.“

    Find a course on single and multi-unit implant placement

    Courses

    You might also be interested in

    A simply straightforward implant system.

    Proven performance, enhanced esthetics.

    Ease, speed, and hygiene, all-in-one with PureSet and LiteSet trays.

    Trusted implant designs, united in one connection.

    Harmonized emergence profiles – from healing to final restoration.

    Welcome to the Mucointegration™ era. Surface chemistry cells can’t resist.

    Ready to talk?

    Fill out the form below and our team will get back to you.

    Warranty program

    Smiles should last a lifetime. That is why Nobel Biocare offers lifetime warranties on dental implants and restorative components.

    In addition, we offer a 10-year warranty on custom-made NobelProcera® prosthetics. We will also replace – free of charge – any implant that fails to remain in the bone in which it was implanted, as well as any Nobel Biocare restorative components on the implant at the time of failure.

    Smiling patients

    References

    See Instructions For Use for full prescribing information, including indications, contraindications, warnings and precautions.

    1. Clinical data combines NobelActive with both TiUnite and TiUltra surfaces. NobelActive TiUltra launched in 2019.
    2. Nobel Biocare. NobelActive® Over 10 years of clinical experience. Science First 2018; Volume 5; Issue 1.   
      Download
    3. Kolinski ML, Cherry JE, McAllister BS, et al. Evaluation of a variable-thread tapered implant in extraction sites with immediate temporization: A 3-year multi-center clinical study. J Periodontol 2014;85(3):386-394   
      Read on PubMed
    4. Irinakis T, Wiebe C. Clinical evaluation of the NobelActive implant system; a case series of 107 consecutively placed implants and a review of the implant features. J Oral Implantol 2009;35(6):283-288.   
      Read on PubMed
    5. Yamada J, Kori H, Tsukiyama Y, et al. Immediate loading of complete-arch fixed prostheses for edentulous maxillae after flapless guided implant placement: a 1-year prospective clinical study. Int J Oral Maxillofac Implants 2015;30(1):184-193.   
      Read on PubMed
    6. Kolinski M, Hess P, Leziy S, et al. Immediate provisionalization in the esthetic zone: 1-year interim results from a prospective single-cohort multicenter study evaluating 3.0-mm-diameter tapered implants. Clin Oral Investig 2018;22(6):2299-2308.   
      Read on PubMed
    7. Ganeles J, Norkin FJ, Zfaz S. Single-tooth implant restorations in fresh extraction sockets of the maxillary esthetic zone: two-year results of a prospective cohort study. Int J Periodontics Restorative Dent 2017;37(2):e154-e162.   
      Read on PubMed
    8. Drago C. Ratios of cantilever lengths and anterior-posterior spreads of definitive hybrid full-arch, screw-retained prostheses: results of a clinical study. J Prosthodont 2018;27(5):402-408.   
      Read on PubMed
    9. Babbush CA, Brokloff J. A single-center retrospective analysis of 1001 consecutively placed NobelActive implants. Implant Dent 2012;21(1):28-35.   
      Read on PubMed
    10. Aspriello SD, Rasicci P, Ciolino F, et al. Immediate loading of NobelActive implants in postmenopausal osteoporotic women: 2-years follow up study. Clin Oral Implants Res 2011;22:Abstract 222. Gultekin BA, Gultekin P, Leblebicioglu B, et al. Clinical evaluation of marginal bone loss and stability in two types of submerged dental implants. Int J Oral Maxillofac Implants 2013;28(3):815-823.   
      Read on PubMed
    11. Pozzi A, Tallarico M, Moy PK. Three-year post-loading results of a randomised, controlled, split-mouth trial comparing implants with different prosthetic interfaces and design in partially posterior edentulous mandibles. Eur J Oral Implantol 2014;7(1):47-61.   
      Read on PubMed