Brånemark System – the original

The most scientifically documented implant system in the world.

Branemark-System_new

  • Clinical success since 1965
    Brånemark System is synonymous with the revolutionary concept of osseointegration, which introduced safe and effective implant treatments to modern dentistry. Brånemark System implants have been in clinical use for more than 45 years and are the most scientifically documented implant system in the world.
  • Exceptional versatility

    Brånemark System offers solutions for an unrivaled choice of treatment options. Implants are available in lengths from 7 mm to 52.5 mm (Zygoma) with narrow to wide platforms, featuring a complete prosthetic assortment.

  • Brånemark System Mk III

    Brånemark System Mk III is indicated for medium to hard bone. Its implant design is based on the original Brånemark System with parallel walls and three cutting chambers. The dedicated drilling protocols are designed to achieve optimal implant stability in all bone qualities.

  • Brånemark System Mk IV

    With its slightly tapered body, Brånemark System Mk IV is designed to maximize initial stability in soft bone. It features a machined collar and shallow cutting edges on threads, which are specifically designed for soft bone indications.

  • Brånemark System Mk III Shorty

    Brånemark System Shorty measures just 5.5 mm in the bone and allows for graftless procedures even in cases with advanced tissue resorption. It is available with machined and TiUnite collar.

  • Brånemark System Zygoma

    Brånemark System Zygoma is the only implant solution on the market for the severely resorbed maxilla when bone grafting is not an option. The implants range from 30 to 52.5 mm in length and are available with machined and TiUnite surface.

  • The original connection for thin marginal soft tissue

    The external hex connection is the original connection developed by Professor P-I Brånemark. It offers unmatched prosthetic versatility with a choice of 6 to 12 abutment positions and a short crown-to-first thread distance, which is ideal for use with thin marginal soft tissue.

  • Also available with internal tri-channel connection

    You like the Brånemark implant body, but prefer using an internal tri-channel connection? Try Replace Select Straight and NobelReplace Straight in medium to dense bone. For overdenture treatments, try Replace Select TC with platform access at tissue level and a straight-forward one-stage protocol for shorter treatment times.

  • Enhanced osseointegration

    Brånemark System features Nobel Biocare’s unique oxidized TiUnite surface, which increases implant stability through faster bone formation and ensures long-term success.

    Learn more about TiUnite

  • Lifetime warranty

    All Nobel Biocare implants and prefabricated non-provisional and non-temporary prosthetic components are covered by a lifetime product warranty.

    Detailed terms and conditions

Case1_Lesley_115image9_tb

Dr. Lesley A. David, Canada – Immediately loaded full-arch rehabilitation using NobelClinician

Indication: 65-year-old male, edentulous in the upper jaw. The dentures were made six years ago.

Solution:  In the maxilla, five Brånemark System Mk III Groovy implants and one NobelSpeedy Shorty implant were placed posteriorly on the left side. As final restoration, a NobelProcera Implant Bridge Titanium with acrylic teeth was used.

View case

Case2_115Bedrossian_image10_tb

Dr. Edmond Bedrossian, USA – Fixed implant restoration of the edentulous maxilla

Indication: 73-year-old healthy female, unable to function with her existing maxillary distal extension partial dentures.

Solution: Removal of the existing maxillary teeth, alveoloplasty to recontour the premaxilla palatally. Immediate placement of 2 NobelSpeedy Groovy implants in the anterior and 2 Brånemark System Zygoma implants in the posterior, followed by a provisional restoration with Immediate Function protocol. As a final restoration, a screw-retained NobelProcera Implant Bridge Titanium framework with acrylic teeth was provided.

View case

Case3_115_Davo_image10

Dr. Rubén Davó, Spain – Complete solution for severely resorbed maxilla

Indication: 60-year-old female with severe bone resorption of the upper and lower jaw with complete dentures.

Solution:  Brånemark System Zygoma and NobelReplace Tapered implants were used to rehabilitate the maxilla. For the mandible, the All-on-4 concept using NobelReplace Tapered implants was used. As final prosthesis, precision-milled fixed NobelProcera Implant Bridges were provided for both the maxilla and the mandible.

View case

Case4_115_Holst_image13

Dr. Stefan Holst, Germany – Full-arch restorations of maxilla and mandible using NobelProcera Implant Bars Overdenture

Indication: Male patient, 73 years old, failing mandibular restoration, extensive atrophy of the alveolar ridges.

Solution: Four NobelReplace Straight implants placed in the interforaminal area of the mandible and six NobelReplace Straight implants in the maxilla, supporting two bar-retained fixed-removable restorations.

View case

  • Wide choice of prosthetic options

    Brånemark System supports the comprehensive range of NobelProcera CAD/CAM dental prosthetics as well as Nobel Biocare’s full range of prefabricated abutments. Made from high quality biocompatible materials with excellent homogeneity, they meet all patients’ esthetic needs.

  • External hex connection
    • Ideal for use with thin marginal soft tissue
    • Short crown-to-first-thread distance
    • 6 to 12 positions, depending on the abutment
    • For Brånemark System implants
  • Internal tri-channel connection
    • Get access to the largest pool of trained restorative clinicians in implant dentistry with preference for the tri-channel connection
    • Unrivaled tactile feel for accurate and predictable abutment placement
    • Color-coded for accurate and fast identification
    • 3 positions
    • For NobelReplace Straight and Replace Select Straight implants
Contact customer service
Please enter an enquiry type
Please enter your name
Please enter your telephone number

Email newsletter sign-up